Home
EMD-2276
Mirrors
RCSB (USA)
EBI (UK)
Contact EMDataBank
Title:
Ribosome structures to near-atomic resolution from thirty thousand cryo-EM particles
Authors:
Bai XC, Fernandez IS, McMullan G, Scheres SHW
Sample:
S.cereviseae 80S ribosome
Method:
Single particle reconstruction (4.6 angstroms resolution)
Summary
Experimental details
Visualization
Map information
Downloads
Sample
Sample name:
S.cereviseae 80S ribosome
Theoretical molecular weight of the sample:
4.2
Components:
ID
Type
Name
Exp. MW (MDa)
Oligomeric details
Recombinant expression
Synthetic
Organism
UniProt identifier
GO identifier
InterPro identifier
Virus identifier
Details
1
ribosome-eukaryote
80S ribosome
4.2
false
Saccharomyces cerevisiae
Experiment
Specimen state:
Particle
Specimen preparation:
pH
Specimen conc.
Details
Staining
Specimen support details
7.45
0.3 mg/mL
3mM Hepes-KOH, 6.6 mM Tris-acetate pH 7.2, 3 mM NH4Cl, 6.6 mM NH4-acetate, 48 mM K-acetate, 4 mM Mg-acetate, 2.4 mM DTT
Quantifoil grids (2/2) with 3 nm thin carbon on top
Vitrification:
Cryogen name
Humidity
Temp.
Instr.
Method
Time resolved
Details
ETHANE
100%
90 K
FEI VITROBOT MARK II
Blot 2.5 seconds before plunging
ms
Imaging:
Microscope
Voltage
Illumination mode
Imaging mode
Cs
Defocus min.
Defocus max.
Nominal mag.
Calibrated mag.
Electron source
Detector
Detector distance
Astigmatism
FEI POLARA 300
300 kV
FLOOD BEAM
BRIGHT FIELD
2 mm
1191 nm
3440 nm
59000
79096
FIELD EMISSION GUN
FEI Falcon (backthinned)
mm
Objective lens astigmatism was corrected at 59,000 times magnification
Specimen holder
Holder model
Tilt min.
Tilt max.
Energy filter
Energy window
Temp.
Temp. min.
Temp. max.
Beam tilt
Electron dose
Other details
Date
GATAN LIQUID NITROGEN
°
°
eV
85 K
80 K
90 K
mrad
16 e/Å
2
15-JUL-2012
Processing
Software:
CTFFIND3, RELION
CTF correction:
each image
Number of particles:
22638
Resolution by author:
4.6 Å
Resolution method:
gold-standard FSC at 0.143 cut-off
Processing details:
Use a newly developed statistical movie processing approach to compensate for beam-induced movement. Use a newly developed statistical movie processing to compensate for beam-induced movement.
Scanned images:
Num. images
Sampling size
OD range
Quant. bit number
Other details
Scanner
200
14 μm/pixel
Every image is the average of sixteen frames recorded by the direct electron detector
Fitting:
PDB
Protocol
Target crit.
Software
B value
Fitting space
PDB chain
Details
3U5B
rigid body
Chimera
REAL
Protocol: Rigid body. The domains were separately fitted by manual docking using program Chimera
3U5C
rigid body
Chimera
REAL
Protocol: Rigid body. The domains were separately fitted by manual docking using program Chimera
3U5D
rigid body
Chimera
REAL
Protocol: Rigid body. The domains were separately fitted by manual docking using program Chimera
3U5E
rigid body
Chimera
REAL
Protocol: Rigid body. The domains were separately fitted by manual docking using program Chimera